Product Preview

NOSHOK version

Original product data

Specifications

modelNumber
12-04S-S-12
subcategory1
Diaphragm Seals
subcategory2
Non-Replaceable Diaphragm Seals
subcategory3
Type 12 Sanitary, Clamped-Style, American Society of Mechanical Engineers - Bioprocessing Equipment (ASME-BPE), Non-Replaceable Diaphragm Seals
Item Name
Type 12 Sanitary Diaphragm Seal, 1/2" NPT Instrument Conn, 316 Stainless Steel, 316 Stainless Steel Diaphragm, 1-1/2" Sanitary Pipe Process Conn
Description
  • Features a flush mount diaphragm and all welded construction, ideal for food & beverage, pharmaceutical and sanitary markets
  • Can be used for remote mounting of pressure instrument(s) with capillary, see options & accessories below
  • Wetted parts and all welded housing are constructed of 316 Stainless Steel for greater strength and durability
  • Accommodates process connection pipes from 1-1/2" through 3" sizes
  • Clamped connection allows ease of installation and removal of seal for maintenance and cleaning
Image Name
https://b1.noshokmedia.com/images/Type-12-Diaphragm-Seals.jpg
Secondary Image
https://b1.noshokmedia.com/images/1-1-2-Nominal-Pipe-Size.jpg
Data Sheet
https://b1.noshokmedia.com/assets/1772268249350-type_12_data_sheet.pdf
User Manual
No User Manual
Dimensions
https://b1.noshokmedia.com/assets/1772268247381-type-5-dimensions.jpg
Additional Assets
https://b1.noshokmedia.com/images/2-1-2-Nominal-Pipe-Size.jpg|https://b1.noshokmedia.com/images/3-Nominal-Pipe-Size.jpg|https://b1.noshokmedia.com/images/Cooling-Elements.jpg|https://b1.noshokmedia.com/images/Distribution-Manifolds.jpg|https://b1.noshokmedia.com/images/Plain-and-Armored-Capillaries.jpg|https://b1.noshokmedia.com/images/Seal-and-Pressure-Transmitter-Switch-Assembly-For-Wastewater-Chemical-Feed.jpg|https://b1.noshokmedia.com/documents/Type_12_Sanitary_Clamped-Style_ASME-BPE_Non-Replaceable.pdf
Additional Information
  • Wetted materials electropolished to 32 μ Ra or better
  • Consider instrument size, pressure range, media composition, ambient and operating temperature, and maximum working pressure when selecting
  • Capillaries and cooling elements are available for elevated process temperatures, see options & accessories below
  • Fill fluid must be compatible with process media; i.e. Glycerin may become volatile in conjunction with a strong oxidizing agent such as chlorine, forms of oxygen or peroxide and nitric acids
Application
  • Water and wastewater
  • Oil and gas
  • Petrochemical
  • Chemical processing
  • Industrial automation
  • Food and beverage
  • Marine
  • Agriculture
  • Steel fabrication
  • Mud pumping
  • Pharmaceutical
  • Pulp and paper
  • Pneumatic
Category
All Categories
Category full name
All Categories > Diaphragm Seals > Non-Replaceable Diaphragm Seals > Type 12 Sanitary, Clamped-Style, American Society of Mechanical Engineers - Bioprocessing Equipment (ASME-BPE), Non-Replaceable Diaphragm Seals
Company Name
NOSHOK, Inc.
Cooling Elements
  • 1/4" NPT x 1/4" NPT Cooling Element (1/4" NPT x 1/4" NPT-CE)
  • 1/2" NPT x 1/2" NPT Cooling Element (1/2" NPT x 1/2" NPT-CE)
  • Works in combination with diaphragm seal to isolate instrument from high media temperatures
  • Recommended for process temperatures above 212 ºF
  • Requires direct mounted system
  • Effective temperature reductions of 200 ºF depending upon ambient conditions
  • High > 212 ºF process temperature, low < -40 ºF process temperature
  • All Stainless Steel construction
Diaphragm Displacement_mm³
190
Diaphragm Material
316 Stainless Steel
Diaphragm Pressure Limits for Fluorocarbon (FKM) Material_psi
2,000
Diaphragm Pressure Limits for Polytetrafluoroethylene (PTFE) Material_psi
2,000
Diaphragm Seal Fill Options
  • Glycerin (GY) Not recommended for use in vacuum applications.)
  • Silicone (SL)
  • Halocarbon® (HL)
  • Neobee M20 (NB)
  • Mineral Oil (MO)
  • Propylene Glycol (PG)
Diaphragm Size_in
1.4
Diaphragm Temperature Limits for Fluorocarbon (FKM) Material_ºF
-10 to 400
Diaphragm Temperature Limits for Polytetrafluoroethylene (PTFE) Material_ºF
-40 to 400
Distribution Manifolds
NOSHOK's Distribution Manifolds connect multiple instruments to one diaphragm seal, eliminating multiple connections that lead to possible leak paths.
Instrument Connection
1/2" National Pipe Thread (NPT)
Instrument Connection Size_in
1/2
Instrument Connection Type
National Pipe Thread (NPT)
Instrument Gauge Size_in
2-1/2 to 4
Instrument Type
Gauges, Transducers, Switches
Maximum Pressure Limits for Glass Transition Temperature (Tg), Tetoron Cotton (TC) Bottom Housing Material_psi
200
Maximum Pressure Limits for Polypropylene (PP) Bottom Housing Material_psi
200
Maximum Pressure Limits for Polyvinyl Chloride (PVC) Bottom Housing Material_psi
80|125|200
Maximum Pressure Limits for Polyvinylidene Fluoride (PVDF) Bottom Housing Material_psi
200
Maximum Temperature Limits for Glass Transition Temperature (Tg), Tetoron Cotton (TC) Bottom Housing Material_ºF
150
Maximum Temperature Limits for Polypropylene (PP) Bottom Housing Material_ºF
140
Maximum Temperature Limits for Polyvinyl Chloride (PVC) Bottom Housing Material_ºF
74|125|150
Maximum Temperature Limits for Polyvinylidene Fluoride (PVDF) Bottom Housing Material_ºF
180
Note for Diaphragm Pressure and Temperature Limits
Metallic diaphragms determined by pressure range of seal type, restricted to temperature range of fill fluid.
Note for Maximum Pressure and Temperature Limits Bottom Housing Material
Metallic lower housings determined by pressure range of seal type, restricted to temperature range of fill fluid.
O-Ring Temperature Limits for Fluorocarbon (FKM) Material_ºF
-10 to 400
O-Ring Temperature Limits for Nitrile Butadiene Rubber (NBR) Material_ºF
-40 to 250
O-Ring Temperature Limits for Polytetrafluoroethylene (PTFE) Material_ºF
-400 to 400
Plain and Armored Capillaries
  • 5 ft. SS Armored Flexible Capillary, 1/4" NPT (AC-02-02-5) per ft. adder (AC-02-02-#)
  • 5 ft. SS Armored Flexible Capillary, 1/2" NPT (AC-04-04-5) per ft. adder (AC-04-04-#)
  • Stainless Steel capillaries available with or without Stainless Steel armor
  • Protects the instrument from high or low process temperatures
  • Allows remote mounting of pressure instrument(s)
  • Select the shortest capillary length possible, as changes in ambient temperature conditions may significantly affect the accuracy and response time of the instrument
  • Standard length 5', others available
  • Installation on analog gauges requires a gauge support and gauge adaptor, or other surface mounting provisions
  • Any level difference between the instrument and the seal will result in a pressure indication error; make sure to compensate for the level difference during calibration of the diaphragm seal assembly if the level difference is known
  • Filling options for capillaries
    • Silicone - specify to 10 or 20 feet (SL-C)
    • Halocarbon® - specify to 10 or 20 feet (HL-C)
Pressure [Max]
Determined by the clamping device and piping system.
Pressure [Min]
{" for Switches_psig":"0 to 30"," for Transducers_psig":"0 to 30"," for Gauges 2-1/2 to 4 in":{" Size_psig":"0 to 30"}}
Process Connection
1/2" National Pipe Thread (NPT)
Product Name
Type 12 Sanitary, Clamped-Style, American Society of Mechanical Engineers - Bioprocessing Equipment (ASME-BPE), Non-Replaceable Diaphragm Seals
Prop 65 Warnings
WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer.  For more information go to www.P65Warnings.ca.gov
Sanitary Clamps and Gaskets
  • Clamp-style fittings are constructed of T304 Stainless Steel; T316 Stainless Steel on request
  • Double hinge design for easy installation and removal
  • Available in sizes from 3/4" to 4"
  • Standard pressure rating of 500 psi at 70 ºF (21 ºC); up to 3,000 psi rating on request
  • Clamp gaskets are available in NBR, EPDM, PTFE and FKM
  • All clamps and gaskets meet FDA and 3A sanitary standards
ASME-BPE Sanitary Clamp
1-1/2" (CR 12)
2" (CR 16)
2-1/2" (CR 20)
3" (CR 24)

NBR Gasket
1-1/2" (BG 12)
2" (BG 16)
2-1/2" (BG 20)
3" (BG 24)

PTFE Gasket
1-1/2" (TG 12)
2" (TG 16)
2-1/2" (TG 20)
3" (TG 24)
Sanitary Pipe Sizes_in
1-1/2
Seal Type
Sanitary clamp, welded diaphragm
Style
Non-Replaceable Diaphragm Seal
Syndication_SET
1
Type
Diaphragm Seal
Upper Housing Material
316 Stainless Steel
Upper Housing Type
Continuous Duty
Product Subcategory Description

A wide selection of non-replaceable NOSHOK diaphragm seals are available to meet multiple application requirements. Options include non-metallic, front flush, high volumetric displacement, standard, elevated and reduced pressure, and sanitary models.

Image
https://b1.noshokmedia.com/assets/1772268249641-type_12_image.jpg
Wiring Diagram
No Wiring Diagram
Marketing Flyers
https://www.noshok.com/images/flyers/Flyer__Brochure_PDFs/Measurement_Solutions_for_the_Water___Wastewater_Industry.pdf
Quick Start Guide
No Quick Start Guide

Epicor/KYKLO version

Adapted for Epicor/KYKLO channel requirements

Specifications

SKU code
12-04S-S-12
Category code
Measurement equipment > Pressure measurement equipment
Product series / family name
Type 12 Sanitary, Clamped-Style, American Society of Mechanical Engineers - Bioprocessing Equipment (ASME-BPE), Non-Replaceable Diaphragm Seals
Short Description
Type 12 Sanitary Diaphragm Seal, 1/2" NPT Instrument Conn, 316 Stainless Steel, 316 Stainless Steel Diaphragm, 1-1/2" Sanitary Pipe Process Conn
Product Image (Full size)
https://b1.noshokmedia.com/images/Type-12-Diaphragm-Seals.jpg
Functions
Type 12 Sanitary, Clamped-Style, American Society of Mechanical Engineers - Bioprocessing Equipment (ASME-BPE), Non-Replaceable Diaphragm Seals
Documents names
https://b1.noshokmedia.com/assets/1772268249350-type_12_data_sheet.pdf
Main function
Diaphragm seal
Benefits
  • Features a flush mount diaphragm and all welded construction, ideal for food & beverage, pharmaceutical and sanitary markets
  • Can be used for remote mounting of pressure instrument(s) with capillary, see options & accessories below
  • Wetted parts and all welded housing are constructed of 316 Stainless Steel for greater strength and durability
  • Accommodates process connection pipes from 1-1/2" through 3" sizes
  • Clamped connection allows ease of installation and removal of seal for maintenance and cleaning
Manufacturer product status
Commercialized