Product Preview

NOSHOK version

Original product data

Commercial information

Inventory
No data
Price
No data

Specifications

modelNumber
1316038
subcategory1
KING-GAGE
subcategory2
KING-GAGE Level Transmitters
subcategory3
Electronic Level Transmitters
subcategory4
550 Series ES2 Slimline Level Transmitters
Item Name
550 Series 0 to 0.69 bar Pressure Range Long Mount ES2 Slimline Level Transmitter
Accuracy
Less than ±0.20% full scale (Includes linearity, hysteresis, non-repeatability errors)
Description
<ul><li>Designed for inventory monitoring</li><li>Robust protection in wash-down environments</li><li>Continuous liquid level measurement</li><li>Excellent stability and repeatability</li><li>Two-wire loop powered (4 mA to 20 mA)</li><li>Available retrofit adapters include Cherry-Burrell LevelMatic, Anderson Instrument, Rosemount / Foxboro, Tank Mate and Wizard</li></ul>
Image Name
https://b1.noshokmedia.com/images/king-gage/550-series-transmitter.jpg
Additional Assets
https://b1.noshokmedia.com/images/king-gage/Downpipe-Check-Valve.png|https://b1.noshokmedia.com/images/king-gage/shell-seal-plug.jpg|https://b1.noshokmedia.com/images/king-gage/Shell-Welding-Protector.jpg|https://b1.noshokmedia.com/images/king-gage/Flush-Weld-Tank-Shell.jpg|https://b1.noshokmedia.com/images/king-gage/5503-Foxboro-Rosemount-use-long-sensor.png|https://b1.noshokmedia.com/images/king-gage/5503-Liquid-scale-adapter-package--use-long-sensor.jpg|https://b1.noshokmedia.com/images/king-gage/5503-Long-Tank-Mate-shell-long-sensor.png|https://b1.noshokmedia.com/images/king-gage/5878-2-Long-Anderson-shell--long-sensor.png|https://b1.noshokmedia.com/images/king-gage/ES2-Slimline-Model-5503--Long-Mount-.png|https://b1.noshokmedia.com/images/king-gage/Long-Cherry-Burrell-shell-long-sensor.png|https://b1.noshokmedia.com/documents/550-Series-ES2-Slimline-Level-Transmitter-catalog-page.pdf|https://b1.noshokmedia.com/documents/5501--5502--5503-Series-ES2-Liquid-Level-Transmitter-data-sheet.pdf|https://b1.noshokmedia.com/documents/Download-6563-Downpipe-Check-Valve-Data-Sheet.pdf|https://b1.noshokmedia.com/documents/EX-Manual-for-550-Series-Transmitters.pdf|https://b1.noshokmedia.com/documents/Installation-Instructions-for-Anderson-Standard-Shell.pdf|https://b1.noshokmedia.com/documents/Installation-Instructions-Flush-Weld-Tank-Shell.pdf|https://b1.noshokmedia.com/documents/Installation-Instructions-for-Cherry-Burrell-Shell-Adapters--304-Stainless-Steel-.pdf|https://b1.noshokmedia.com/documents/Installation-Instructions-for-ES2-Short-Mount-Transmitter-5503.pdf
Additional Information
ES2 Slimline Transmitter<ul><li>Robust protection in wash-down environments</li><li>Continuous liquid level measurement</li><li>Two Wire Loop Powered (4–20 mA)</li></ul>KING-GAGE® ES2 transmitters provide liquid level measurement for inventory monitoring. Add to their rugged reliability the major benefits of simplified service and maintenance. Performance characteristics of these transmitters include excellent stability and repeatability (better than 0.02% FS). Transmitter span accommodates a 3:1 turndown ratio (3:1 turndown ratio is applicable to 0–10 and 0–30 nominal range, refer to specifications for detailed span adjustment available on specific range models.) to match the application pressure range (i.e. tank depth) and the 4-20 mAdc output is compatible with PLCs or other control architecture using analog I/O.<br><br>KING-GAGE® ES2 transmitters are applicable to most tanks or process vessels whose contents remain at normal atmospheric pressure. They measure hydrostatic head pressure created by liquid depth in the tank and are unaffected by foaming or internal obstructions such as agitators. Unlike load cells, pressure based measurement has lower installation cost and is far simpler to maintain thus ensuring more reliable readings.<br><br>Transmitters used in sanitary processing must often endure cycles of rapid temperature fluctuation. Wash-down environments produce significant condensation on metallic surfaces that coupled with aggressive cleansing agents demand robust protection for these instruments. The ES2 transmitter's enhanced design uses encapsulation for full isolation of the internal electronics. This extends to the IP68 grade M12 signal connector that ensure integrity and long term reliability. You can be assured of a transmitter truly built for the demands and expectations of today's processing environment.
Anderson Shell Adapters (304 Stainless Steel)
5878-2: Long Anderson Shell, Use Long Sensor
Application
<ul><li>Food and beverage</li><li>Chemical processing</li><li>Power generation</li><li>Pharmaceutical</li><li>Water and wastewater</li><li>Pulp and paper</li><li>Marine</li></ul>
Category full name
KING-GAGE > Level Transmitters > Electronic Level Transmitters > 550 Series ES2 Slimline Level Transmitters
Cherry-Burrell Shell Adapters (304 Stainless Steel)
Adapters available in 304 SS only<br><br>5640-2: Long Cherry-Burrell Shell, Use Long Sensor
Company Name
NOSHOK, Inc.
Connection/Termination
Cable with Integral Molded Connector (M12)
Downpipe Check Valve
Downpipe Check Valve<br><br>6363: Downpipe Float Check Valve, 3/4" NPT Connections<br><br>6563-10: Downpipe Float Check Valve, 3/4" NPT Outlet, 3/8" Tube Inlet<ul><li>Prevents siphoning or backflow of liquid through a downpipe installed in tank level gauging applications</li><li>Utilizes a specially designed float pin that rises up to seal the valve shut when liquid enters from the downpipe through the bottom of the unit</li><li>The advantage of a float check is that it doesn't create a pressure drop that would affect the level gauge reading (Spring-loaded check valves can impact the accuracy of a downpipe or bubbler system if installed at the tank entry point)</li></ul>NOTE: Not recommended for use with heavy diesel fuel oil or other high viscosity liquids. Installation in conjunction with a gate valve will permit removal of check valve for inspection and cleaning. (We recommend cleaning the check valve once per year to ensure reliability.)<br><br>Material: 304 Stainless Steel, Nylon (float), FKM (seals)<br>Maximum Pressure: 150 psig<br>Inlet/Outlet: 3/4" NPT-female<br>Weight: 1.2 lb (0.5 kg)
ES2 Signal Connection
The external connector of the ES2 transmitter affords an impermeable barrier against moisture infiltration of the transmitter housing. This connector receptacle has a metric M12 screw collar and is intended for plug type molded cable assemblies designed for 4-pole signal termination. Our ES2 transmitter package also includes a molded M12 cable (32 ft/10 m) to simplify installation and ensure a sealed connection at the unit - this molded cable meets IP68 standards for ingress protection.
Electrical Direct Current (DC) Input Voltage (Excitation)_V
14 to 40
Electrical Output Current (Milliamperes Direct Current (DC) (mAdc))_mA
4 to 20
Flush Weld Tank Shell
Flush Weld Tank Shell<br><br>1777-2: Weld-in Tank Shell, Short Length Sensor, 316L SS, Length 1-7/8" (48 mm)<br>Use for single wall (non-insulated) tank only!<br>1777: Weld-in Tank Shell, Standard Length Sensor, 316L SS, Length 6-1/4" (159 mm)<br>Use for single wall or insulated wall up to 4-1/2" thick<br>1777-3: Weld-in Tank Shell, Long Length Sensor, 316L SS, Length 8-1/2" (216 mm)<br>Use for insulated wall up to 6-3/4" thick
Foxboro/Rosemount Shell Adapters (304 Stainless)
5905-2: 6" Ext. Foxboro/Rosemount, Use Long Sensor(Minimum 5 pcs Order Required (Special))
Installation Options
The KING-GAGE® ES2 transmitter offers a choice of configurations to match your application needs. The integral stainless steel housing shown here includes a watertight connector for signal cable installation. Mounting lengths offered are intended to mate with tank fittings on non-insulated (single-wall) or insulated wall tanks. Adapters provide additional mounting options when retrofitting systems from other manufacturers.
Linearity (Worst Case)
Less than ±0.13% Full Scale<br>Hysteresis (Worst Case)<br>Less than 0.05% Full Scale
Liquid Scale Adapter (304 Stainless Steel)
1749-35-1: Liquid scale adapter package, use long sensor
Mounting
Flush-mounting configurations are intended to meet the 3-A Sanitary Standards for clean-in-place applications. The ES2 transmitter fits directly into KING-GAGE® tank shells or with an adapter on other manufacturers' mounting shells.<br><br>Available Retrofit Adapters<ul><li>Cherry-Burrell LevelMatic</li><li>Anderson Instrument</li><li>Rosemount/ Foxboro</li><li>Tank Mate</li><li>Wizard</li></ul>
Mounting Application
Long Mount (Insulated Wall Up to 6.75 in./171 mm; or Adapter for Non-KING "Standard" Shell)
Nominal Span Adjustment Range_psig
0 to 10
Non-Repeatability (Worst Case)
Less than 0.02% Full Scale
Note for Span Adjustment Range
IMPORTANT! Accuracy, linearity, and non-repeatability values are based on nominal range.
Operating Limit (Maximum Pressure)
Pressure above 300% nominal range (over-range) will result in damage to the transmitter (200% may cause a shift in calibration).
Operating Pressure [Max]
{"_bar":0.69,"_psig":10}
Operating Pressure [Min]
{"_bar":0,"_psig":0}
Operating Temperature [Max]
{"_ºC":79,"_ºF":175}
Operating Temperature [Min]
{"_ºC":-17,"_ºF":0}
Performance and Reliability
Unlike some other transmitters, ES2 has virtually no position sensitivity and its fast thermal recovery accommodates sanitary process environments. The ES2 transmitter's smaller diameter diaphragm face minimizes exposure to accidental impact and permits retrofit installation in many existing tank level fittings. Isolated meter terminals simplify accurate calibration of span and zero. Generous load capacity (up to 1300 ohms at 40 Vdc) can support extended cable runs or multiple loop receivers. We've provided ES2 transmitters with additional isolation from both moisture and corrosive potentials. The internal electronics are environmentally encapsulated, plus the external signal connection is hermetically sealed at the transmitter housing to reduce the opportunity for infiltration. These measures significantly add to the durability of our KING-GAGE® ES2 transmitter.
Pressure Media
Gas or liquids compatible with 316 Stainless Steel (diaphragm); Silicone rubber (o-ring). All other wetted parts 316L.
Pressure Test Fixture
5668-1: Short Mount Fixture<br>5668-2: Standard Mount Fixture<br>5668-3: Long Mount Fixture
Product Name
550 Series ES2 Slimline Level Transmitters
Product Warranty
All KING-GAGE®, a NOSHOK Company products are guaranteed to be free from defects in material and workmanship for one (1) year from the date of purchase.<br><br>Repair Services Warranty: 90 days limited warranty.
Prop 65 Warnings
<div style="margin-left:20pt"> <img src="/asset/warning.png" style="width: 17pt; vertical-align: baseline; margin-left:-20pt"> <b style="font-size: 14pt; font-weight: bold;">WARNING:</b> This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to <a href="https://www.p65warnings.ca.gov">www.P65Warnings.ca.gov</a> </div>
Range of Adjustment
<html>0 to 83 inH<sub>2</sub>O through 0 to 277 inH<sub>2</sub>O, 0 to 2.1 mH<sub>2</sub>O through 0 to 7.0 mH<sub>2</sub>O</html>
Sanitary Configurations
These sensors are especially suited to a wide range of sanitary applications on storage or continuous processing vessels. The 316 stainless diaphragm is appropriate for flush mount, clean-in-place installation employing an FDA-approved silicone rubber O-ring seal to achieve the crevice-free, positive compression seal between diaphragm and tank liner. Sanitary tank mountings include flush weld mountings with product contact surfaces of 316L stainless. (Quick disconnect sanitary adapters are also available for sensor mounting.) You can choose from a number of KING-GAGE® display options to complement the ES2 for a complete tank level gauging system. These include digital indicators, HMI touch panels, and integrated networking solutions. Accurate tank gauging can be achieved using KING-GAGE® indicators that convert the proportional output into a volumetric measurement of tank level.
Series
550
Service and Replacement Parts
1747-40: FKM O-Ring<br>1751: Clamp Nut<br>6495-125: O-Ring, Housing End Cap seal<br>6554-40: O-Ring, Silicone Rubber (Standard) <br>6554-44: O-Ring, Oversized (Special Application)<br>5378-2-1: Field Wireable Connector (M12) 4-pin Female with Color Reference<br>5630-5: FRP Junction Enclosure (includes 2 Cable Fittings)<br>8027-10: ES2 Molded Cable with Integral M12 Plug Connector (32 ft /10 m) on One End<br>8027-25: ES2 Molded Cable with Integral M12 Plug Connector (82 ft / 25 m) on One End
Shell Seal Plug
2584-4: Shell plug, fits short shell<br>2584-3: Shell plug, fits standard shell, tri-clamp, and short adapters<br>2584-6: Shell plug, fits long shell, long adapters
Shell Welding Protector
5664-1: Shell face protector, fits all weld-in shells
Span Adjustment Range [Min]
{"_psig":"0 to 3"}
Tank Level Display
Output from the ES2 transmitter can be monitored on KING-GAGE® indicators and multiple tank displays. Each of these display options also provide excitation power (24Vdc) to the transmitter through the signal loop cable.<br><br> KING-GAGE® indicators enable tank level to be represented as total volume, weight or depth of contents. Options include network connectivity including Ethernet.
Tank-Mate Shell Adapters (304 Stainless Steel)
5641-2: Long Tank-Mate Shell, Use Long Sensor
Type
Slimline Level Transmitter

Graybar version

Adapted for Graybar channel requirements

Product does not satisfy the Graybar channel schema

Specifications

Manufacturer Provided Shop SKU
  • 1316038
MPN_Mfg Number
  • 1316038
Category ID
  • Required value is missing.
  • No matching value found for "KING-GAGE" (subcategory1) and "KING-GAGE Level Transmitters" (subcategory2).
Manufacturer Provided Title
  • 550 Series 0 to 0.69 bar Pressure Range Long Mount ES2 Slimline Level Transmitter
Manufacturer
  • NOSHOK
Manufacturer Provided Short Description
  • 550 Series 0 to 0.69 bar Pressure Range Long Mount ES2 Slimline Level Transmitter
Main ImageMiraklDisplay
  • https://b1.noshokmedia.com/images/king-gage/550-series-transmitter.jpg
Manufacturer Part Number
  • 1316038
Brand
  • NOSHOK
Category Hierarchy
  • KING-GAGE > Level Transmitters > Electronic Level Transmitters > 550 Series ES2 Slimline Level Transmitters
Description
  • Recommended value is missing.
Manufacturer Provided Long Description
  • Designed for inventory monitoring; Robust protection in wash-down environments; Continuous liquid level measurement; Excellent stability and repeatability; Two-wire loop powered (4 mA to 20 mA); Available retrofit adapters include Cherry-Burrell LevelMatic, Anderson Instrument, Rosemount / Foxboro, Tank Mate and Wizard
Product Grouping
  • KING-GAGE